702.03.100
DELTA-comb Манометр дифференциального давления,
с встроенным манометром рабочего давления и микропереключателем, с дополнительными одобрениями,
НР 100 мм
Отправить запрос


Описание
Файлы для скачивания

Applications

  • flow protection
  • safeguard flowin steam boilers

Special Features

  • Working pressure gauge integrated as a standard featureenables the central monitoring of differential pressure andworking pressure in one measuring instrument
  • One or two adjustable microswitches respectively
  • High repeatability of the switchpoints
  • High working pressure (static pressure) 25 bar
  • Overload value either side 25 bar
  • Solid case construction for protection against external mechanical effects
  • Three cast-on mounting brackets for wall mounting
  • Long service life
  • Component approval to ensure flow protection in accordance with DIN 32 727 Reg.-No.: 1B0162000, and also to safeguard flowin steam boilers in accordance with VdTÜV note of instructions "flow 100", component sign number TÜV.SW.00- 030

Description

Nominal size 
Differential pressure gauge: Ø 100mm 
Working pressure gauge: Ø 23 mm 

Accuracy class 
Differential pressure gauge: 2.5 
Working pressure gauge: 4 

Scale ranges 
Differential pressure: 0 ... 0.25 to 0 ... 25 bar 
Working pressure: 0 ... 25 bar 

Working pressure max. (static pressure) 25 bar
  • Differential pressure gauge with integrated working pressure gauge DELTA-plus Model 702.03.100 (see data sheet PM 07.15)
  • Differential pressure gauge with integrated working pressure gauge and microswitch DELTA-comb, Model 702.02.100 (see data sheet PM 07.16)
  • Differential pressure switch DELTA-switch, Model 851.02.100 (see data sheet PM 07.17)
  • Differential pressure transmitter DELTA-trans, Model 891.34.2189 (see data sheet PM 07.18)

These differential pressure gauges are particularly intended for flow safeguarding in heat transfer oil plants according to DIN 32 727 and in hot-water apparatus according to VdTÜV note of instructions "flow 100". This gauge has been designed for connection to standard throttling devices (e.g. orifice gauges, nozzles or similar) that operate according to the differential pressure principle and are interconnected via differential pressure lines and shut-off devices.

 

Apart from the display of the differential pressure, these applications require, as a rule, the display of the current working pressure.For this reason, a working pressure gauge is integrated in the differential pressure gauge DELTA-comb as a standard feature. An additional measuring point involving additional expenses forpiping and mounting is thus no longer required.

 

The white dial of the working pressure gauge distinctly stands out against the blue background of the display of the differential pressure gauge, thus enabling a quick and safe reading of both quantities to be measured.

 

Имя файла
DS_PV2719_GB_6948.pdfСкачать (389.65 Кб)
Вернуться к списку