The intrinsically safe melt pressure transducer series EMT based on the proven melt pressure transmitter series MDT. The integrated, PTB-approved, 2-wire mAmp amplifier converts the process pressure into an proportional output signal. The 2-wire mAmp amplifier technique is insensitive to noise and well suited for economical long cable runs. The EMT-series 432/463 features an integral thermocouple that allows pressure and temperature to be measured in a single sensor. Many of the features found in Dyniscos standard MDT-series have been incorporated into the EMT-series, including proven bonded strain gauge construction for stable operation, a flexible armored capillary between the amplifier housing and the rigid stem and a flush diaphragm. Another advantage is the electrical built-in calibration.
  • Intrinsically safe according EX-safety class EEx ia IIC T5 up to 80╟C
  • Intrinsically safe according EX-safety class EEx ia IIC T1-T4 up to 85╟C
  • Installation for media temperature up to 400╟C
  • Flexible capillary between rigid stem and housing
  • Electrical built-in calibration
  • Integral thermocouple for simultaneous temperature measurement at the media
    Диапазон давления0 - 17 bar to 0 - 2000 bar
    Выход4 - 20 mA
    Точность±1.0% FSO
    Резьбовое соединение1/2-20 UNF
    Электрическое соединениеBendix PT02A-10-6P
  • Имя файла
    Подробное описаниеСкачать (69.06 Кб)